PH-SC-SC-SM-22-2m
PH-SCA-LCA-SM-22-2m
PH-SCA-FCA-SM-32-2m
PH-SC-LC-SM-22-2m
Previous slide
Next slide
Duplex Patch Cords
Features
- Flexible Angle Boots: Can be set to any angle & will remain in that angle
- Single Mode- G.652D or G.657A1 fiber
- Connectors: SC, LC, FC or ST – In UPC and SC, LC and FC in APC polishing
- Cable standard diameter 2mm. 3mm diameter also available
For technical specifications and ordering information see the flipbook underneath.
Parameter | LC/UPC | SC/UPC | FC/UPC | ST/UPC | FC/APC | LC/APC | SC/APC |
---|---|---|---|---|---|---|---|
Insertion Loss (Typ) | 0.10 dB | 0.10 dB | 0.10 dB | 0.10 dB | 0.10 dB | 0.15 dB | 0.15 dB |
Insertion Loss (Max) | 0.30 dB | 0.30 dB | 0.30 dB | 0.30 dB | 0.30 dB | 0.30 dB | 0.30 dB |
Return Loss (Typ) | 58 dB | 58 dB | 58 dB | 55 dB | 65 dB | 65 dB | 65 dB |
Return Loss (Min) | 55 dB | 55 dB | 55 dB | 50 dB | 60 dB | 60 dB | 60 dB |
Operating Wavelength | 1490nm, 1310nm and 1550nm | ||||||
Fiber Size | 9/125um, Single Mode, ITU G.652D/ G.657.A1 | ||||||
Cable Type | Indoor, LSZH Jacket | ||||||
Cable Color | Yellow | ||||||
Operating Temperature | -20 to +70°C | ||||||
Storage Temperature | -20 to +70°C | ||||||
Complying Standards | IEC 61753-021-2 Fibre optic interconnecting devices and passive components performance standard & Telcordia GR-326 | ||||||
Mating Durability | 500 Cycles minimum (as per IEC 61300-2-2) | ||||||